Machine Components - SN-2816, SN-4024, SN-4036

Machine components for 2816, 4024, 4036.

Machine Components Component Model No/ID Description Common Issues
Laser Power Supply HY-ESA100 Main power supply that provides the CO2 laser tube power.  
36V Power Supply HW360-36 Power supply which gives power to the drivers.  
JMD Power Supply JMD30-245 Powers red dot diode and temperature guage.  
JMD Power Supply JMD2012 Powers water pump.  
JMD Power Supply JMD30-24 Powers LED Lights.  
Water Pump TL-C01/S-C12-2008 Pumps water through the tube to cool the tube. Can have the water tubes improperly installed.
Water Flow Switch 2004200062601 Ensures enough water is flowing into the tube. It will tell the machine if there is not enough water flowing through, enabling the water protect signal. The flow switch can malfunction. It is the most common component to stop working properly. To prove this you must bypass the flow switch and see if the laser can still fire. If so, a new switch is needed.
X and Y Drivers 3DM580 Send signals to the X and Y stepper motors Sometimes the X and Y driver shorts, thus sending the motor improper signals. This would cause the laser print to be distorted. The solution would be to send new drivers.
Z Driver KD-2MD530 Sends signals to the Z motors to move the Z-Table.  
Fan IF12038HBL Keeps machine cool and expels hot air.  
Control Panel  RDC6442S-B User interface which allows you to control the machine, this is directly connected to the controller. It is possible for the button contacts to malfunction. This will make it difficult for the user to press down buttons. A new control panel will be needed.
EMI Filter FT121-15 Filters out noise that it may have gained passing though outlet sources (Air Pump, Etc.)  
Contact Blocks ZB2-BE102C To connect the E-Stop and key switch to the system.  
LED Lights 9290023146 Lights up the workspace.  
Controller RDC6442S-B Controls various components within the machine. A lot of short circuiting issues. Troubleshooting required whenever investigating controller issues.
CO2 Laser Tube RECIW2 Tube which fires the laser. Laser tube can lose power over time. If you put masking tape in laser path to test laser and the laser leaves a feint mark or no mark, a new tube is needed. Also, laser tube is defective if two marks are shown, thus indicating that the laser tube is splitting.
X Stepper Motor 573S09-L Used to move the laser head around the workspace.  
Y Stepper Motor 24HC3005-01 Used to move the laser head around the workspace.  
Z Stepper Motor 57-H250E208 User to move the Z table up and down.  
Temperature Gauge FY5135B Determines the temperature of the water to indicate whether or not the water is hot. When the temperature gauge shows HHH, it either means the signal wires are touching each other, or the probe itself is damaged due to either moisture buildup within the probe, exposure to extreme heat or severe twisting/bending of the probe wire. This indicates that the temperature gauge is now defective due to some sort of short and must be replaced.
Newer Temperature Guage BC-0303DW Determines the temperature of the water to indicate whether or not the water is hot, this newer temperature gauge has an option to switch the units between C and F When the temperature gauge shows HHH, it either means the signal wires are touching each other, or the probe itself is damaged due to either moisture buildup within the probe, exposure to extreme heat or severe twisting/bending of the probe wire. This indicates that the temperature gauge is now defective due to some sort of short and must be replaced.
Inductive Limit Switch SN04-N Component which tells the machine what the size of the workspace is. These switches are also used to tell whether any of the panels are open. Shorting with the inductive limit switch can cause the limit switch to send incorrect or no signal to the controller.